In Kenya's rapidly growing construction sector, one dangerous practice continues to appear on construction sites: placing reinforced concrete columns directly on top of existing machine-cut stone masonry walls. This structural error represents a fundamental misunderstanding of load distribution principles and has contributed to numerous building failures across the country. This article examines why this practice is structurally unsound, the engineering principles involved, and proper alternatives for Kenyan construction projects.
Understanding the Fundamental Problem
What Are Masonry Walls Designed For?
Masonry walls, whether constructed from machine-cut stones, bricks, or concrete blocks, are designed primarily to resist uniformly distributed loads. These walls excel at carrying loads that spread evenly along their length, such as:
- The weight of the wall itself (self-weight)
- Evenly distributed roof loads transferred through continuous wall plates
- Floor loads that bear uniformly along the wall length
- Lateral loads from wind or earth pressure
The structural capacity of masonry walls is calculated based on the compressive strength of the masonry units, the mortar type, and the wall's slenderness ratio. Design standards assume that loads are distributed relatively uniformly across the wall's cross-sectional area.
What Are Concentrated Loads?
Concentrated loads, also known as point loads, are forces applied to a very small area of a structural element. A reinforced concrete column transfers its entire load through a relatively small base area compared to the length of a wall. When a column sits on a wall, it creates intense stress concentration at that specific point.
For example, a typical column might measure 230mm x 230mm (9" x 9"), creating a bearing area of approximately 52,900 mm². If this column carries a load of 500 kN from multiple floors above, the bearing stress under the column base is approximately 9.45 N/mm² or MPa. This concentrated stress must be distributed safely into the supporting element below.
Why Masonry Walls Cannot Support Column Loads
1. Stress Concentration and Splitting
When a concentrated load from a column is applied to a masonry wall, several failure mechanisms can occur:
Vertical Splitting: The intense compressive stress under the column base creates lateral tensile stresses in the masonry units. Since masonry has very low tensile strength (typically 5-10% of its compressive strength), these lateral stresses cause vertical cracks to propagate through the masonry units. This splitting is particularly severe at wall ends or in narrow wall sections.
Local Crushing: Even before splitting occurs, the masonry units directly under the column may experience compressive stresses that exceed their capacity, leading to localized crushing. The mortar, being weaker than the masonry units, tends to be squeezed out of the joints, transferring stress to the masonry units and inducing additional tensile stresses.
2. Load Dispersion Limitations
Building codes recognize that concentrated loads can spread through masonry at specific angles. The Eurocode and British Standards (which influence Kenyan practice through the Building Code) typically assume loads spread at 60-degree angles from the point of application. However, this dispersion:
- Takes significant vertical distance to spread adequately
- Is limited by wall length, openings, and movement joints
- Provides insufficient distribution in thin walls common in Kenyan construction
- Does not account for the weakness of unreinforced masonry in handling concentrated stresses
For a column load to adequately disperse into a 200mm (8-inch) thick masonry wall, the load would need to spread over a considerable height below the bearing point. In practice, typical masonry walls lack the depth and continuity required for safe dispersion of significant column loads.
3. Differential Settlement and Movement
Columns and masonry walls respond differently to loads:
- Elastic Deformation: Reinforced concrete columns have different elastic properties than masonry walls, leading to differential movement under load
- Creep: Masonry exhibits significant creep (time-dependent deformation) under sustained loads, which can be 1.5 to 3.0 times the initial elastic deformation depending on the masonry type
- Thermal Movement: Different thermal expansion coefficients between concrete and masonry create movement incompatibilities
- Moisture Movement: Masonry undergoes moisture-related dimensional changes that concrete does not experience to the same degree
These differential movements can create additional stresses at the column-wall interface, potentially leading to cracking, loss of bearing, or progressive failure.
4. Lack of Continuity in Load Path
Structural engineering principles require a continuous, clearly defined load path from the highest point of a structure down to the foundation. When columns are placed on masonry walls:
- The load path is interrupted and redirected laterally through the wall
- The wall was not designed or reinforced to handle this load redistribution
- There is no adequate mechanism to transfer the concentrated load to properly designed foundations
- The foundation under the wall may not have been sized to handle the concentrated column load
International Building Standards and Codes
Kenyan Building Code Requirements
The Kenya Building Code (Legal Notice No. 47 of 2024) and the earlier Local Government (Adoptive By-Laws) (Building) Order of 1968, which still govern many aspects of construction in Kenya, reference British Standard CP 111 "Structural recommendations for load-bearing walls" for masonry design.
These codes establish that:
- Load-bearing walls must be designed for the loads they will carry
- Structural calculations must account for combined axial and bending stresses
- Concentrated loads require special consideration and design
The codes do not permit the arbitrary placement of columns on walls not designed for such loads.
International Engineering Standards
Eurocode 6 (EN 1996): This European standard for masonry structures requires that concentrated loads be addressed through specific design provisions, including:
- Enhanced bearing stress calculations
- Proper load dispersion analysis
- Use of bearing plates or padstones where necessary
- Special reinforcement for concentrated loads
TMS 402/602 (U.S. Masonry Standards): The Masonry Society's Building Code Requirements specify that:
- Concentrated loads must act on solid masonry units or units filled solid with mortar or grout
- Allowable stresses may be increased by only 25% when concentrated loads act on the full wall thickness
- Masonry elements carrying concentrated loads require specific design and detailing
ACI 530 (Masonry Structures): This standard requires structural calculations for masonry columns and walls considering combined axial and bending stresses, and specifies reinforcement requirements for distribution of concentrated vertical loads.
Common Scenarios Where This Error Occurs in Kenya
1. Vertical Extensions of Existing Buildings
Property owners frequently add additional floors to existing buildings to maximize rental income. In these cases, contractors sometimes attempt to support new columns on the existing masonry walls that were only designed for single-story construction. This is extremely dangerous as:
- The original wall was not designed for the concentrated loads
- The foundation below the wall cannot support the additional load
- No proper load assessment was conducted before the extension
2. "Skeleton Infill" Construction Done in Wrong Sequence
The proper sequence for framed structures is:
- Construct the complete structural frame (columns, beams, slabs)
- Build masonry walls between the frame as non-load-bearing infill
However, a dangerous practice observed in Kenya involves:
- Building masonry walls first
- Attempting to construct columns later by breaking through the walls or placing columns on top of walls
This violates fundamental structural principles and creates dangerous conditions.
3. Renovation Projects
During renovations, untrained contractors may introduce new column supports without understanding the structural implications. This often occurs when:
- Creating open-plan spaces by removing walls
- Adding rooftop structures or water tanks
- Installing heavy equipment that requires additional structural support
Proper Engineering Solutions
Option 1: Masonry Pilasters
When concentrated loads must be carried by masonry construction, the proper solution is a masonry pilaster - not placing a column on a wall. Pilasters are:
Definition: Thickened sections of masonry wall, bonded integrally with the wall, designed specifically to carry concentrated loads from beams, trusses, or other structural elements.
Design Requirements:
- Must be designed from the outset as part of the wall system
- Require proper reinforcement in grouted cells
- Must have adequate dimensions (width not more than 4 times thickness)
- Need proper bonding with the adjacent wall
- Require specific detailing of reinforcement, ties, and grout
Capacity: When properly designed, masonry pilasters can have significant load-carrying capacity, sometimes exceeding that of similarly-sized concrete columns, while maintaining structural integrity with the wall system.
Option 2: Independent Column Support System
The structurally sound approach for multi-story buildings is:
- Proper Foundation Design: Columns must bear on foundations specifically designed for concentrated loads, such as:
- Pad footings dimensioned for the column load
- Grade beams that distribute loads
- Properly reinforced strip footings
- Continuous Columns: Columns should run continuously from foundation to roof without interruption or load transfer to inadequate intermediate supports
- Wall as Infill Only: Masonry walls between columns serve as:
- Non-load-bearing partitions
- Lateral stability elements (when properly designed as infill)
- Architectural and environmental enclosure
Option 3: Bearing Plates and Padstones for Limited Situations
When beam reactions must bear on masonry walls (not columns), proper engineering requires:
Bearing Plates: Steel plates that distribute concentrated loads over a larger area of masonry. The plate must:
- Be of adequate thickness to prevent bending
- Extend sufficiently to reduce bearing stress to acceptable levels
- Be properly bedded on high-strength mortar
- Have the masonry course beneath it solidly grouted or built with solid units
Padstones: Reinforced concrete blocks cast into the masonry to provide a concentrated bearing area with adequate strength. These require:
- Proper reinforcement design
- Adequate dimensions
- Integration with the wall system
- Verification that the wall below can distribute the load
Important Limitation: Even with bearing plates and padstones, these solutions are appropriate for beam reactions and limited concentrated loads, NOT for supporting columns that will carry loads from multiple floors above.
Option 4: Transfer Structures
When unavoidable circumstances require load transfer (such as in renovation projects), the solution is a properly engineered transfer structure:
Transfer Beams: Deep reinforced concrete or steel beams designed to:
- Carry the column loads from above
- Distribute these loads to adequate supports on either side
- Be properly connected to the existing structure
- Have foundations verified for the new loading condition
Transfer Slabs: Thick reinforced concrete slabs that can distribute loads over a larger area, though these are complex to design and construct.
Critical Requirement: Any transfer structure must be designed by a qualified structural engineer with proper calculations, and must be constructed under competent supervision with appropriate inspections.
Case Studies: Building Failures in Kenya
Pattern of Failures
Research on building collapses in Kenya reveals consistent patterns:
- Prevalence: Since 1974, numerous building failures have been documented in Kenya, with concentrated occurrences in Nairobi and other urban centers
- Causes: Structural failures often stem from:
- Inadequate foundations
- Poor quality materials
- Substandard workmanship
- Lack of proper engineering supervision
- Violations of building codes
- Warning Signs: Many collapsed buildings showed warning signs including:
- Visible cracks in walls and columns
- Bent or leaning columns
- Differential settlement
- Progressive cracking over time
The Structural Sequence Error
A specific issue identified in failed buildings is the construction sequence error where "masons build the walls first and columns later. They are supposed to build the skeletal structure first and then the walls." This practice, which may involve placing columns on top of walls, fundamentally compromises structural integrity.
Economic and Human Cost
Building failures in Kenya have resulted in:
- Significant loss of life and injuries
- Economic losses running into billions of shillings
- Displacement of families and businesses
- Loss of investor confidence
- Litigation and criminal proceedings
According to a 2015 audit commissioned by President Uhuru Kenyatta, only 42% of buildings in Nairobi were found fit for habitation, indicating the scale of the structural safety challenge.
The Role of Professional Engineers
Legal and Ethical Requirements
Under the Engineers Act (Cap 530) and regulations by the Engineers Board of Kenya (EBK), structural design must be conducted by qualified and registered engineers. The National Construction Authority (NCA) requires that:
- All construction works have proper designs approved by relevant authorities
- Structural drawings must be signed and stamped by registered engineers
- Construction must be supervised by qualified professionals
- Inspections must be conducted at critical stages
Design Responsibilities
Professional structural engineers must:
- Conduct proper load analysis including:
- Dead loads from all structural elements
- Live loads per code requirements
- Environmental loads (wind, seismic)
- Load combinations per relevant standards
- Design all structural elements with:
- Adequate safety factors
- Proper material specifications
- Clear load paths
- Connection details
- Provide construction documentation including:
- Detailed structural drawings
- Specifications for materials and workmanship
- Construction sequence requirements
- Special inspection requirements
- Supervise critical construction stages to ensure:
- Proper execution of the design
- Quality of materials and workmanship
- Compliance with approved drawings
- Resolution of any field issues
Recommendations for the Kenyan Construction Industry
For Property Owners and Developers
- Engage Qualified Professionals: Always hire registered structural engineers for structural design, not just architects or general contractors
- Verify Credentials: Confirm registration with EBK and NCA before engaging professionals
- Obtain Proper Approvals: Ensure all plans are approved by county authorities before construction
- Budget for Quality: Adequate structural design and supervision is an investment in safety and longevity
- Avoid Shortcuts: Reject proposals to place columns on walls or other non-standard practices
- Question Suspicious Practices: If something looks wrong on your construction site, stop work and consult a qualified engineer
For Contractors and Artisans
- Follow Approved Drawings: Construct exactly as shown on engineer-approved drawings
- Correct Sequence: Always construct the structural frame (columns, beams) before infill walls
- Seek Clarification: When in doubt, consult the supervising engineer rather than improvising
- Quality Materials: Use specified materials with proper certifications
- Proper Workmanship: Ensure proper concrete mixing, placement, curing, and masonry construction
- Continuous Learning: Attend training on proper construction techniques and building codes
For Regulatory Bodies
- Strengthen Enforcement: Increase inspection capacity and consequences for violations
- Public Education: Conduct awareness campaigns on structural safety
- Professional Development: Provide ongoing training for inspectors and enforcement officers
- Streamline Processes: Make approval processes efficient to reduce incentives for illegal construction
- Transparency: Make inspection results and building approvals publicly accessible
- Consequences: Prosecute professionals and contractors involved in structural failures
Conclusion
The practice of placing reinforced concrete columns on machine-cut masonry walls represents a dangerous structural error that violates fundamental engineering principles and building codes. Masonry walls are not designed to carry concentrated vertical loads and lack the structural capacity, load distribution mechanisms, and continuity required to safely support columns.
This practice continues in Kenya due to several factors:
- Lack of awareness among property owners and unqualified builders
- Cost-cutting measures that bypass proper engineering
- Weak enforcement of building regulations
- Shortage of qualified supervision on construction sites
The consequences can be catastrophic. Proper structural design requires that concentrated loads from columns be carried on foundations specifically designed for that purpose, with continuous load paths through properly designed structural elements.
For Kenya's construction industry to achieve the safety standards necessary for protecting lives and investments, several critical actions are needed:
- Mandatory professional involvement in all structural construction
- Strict enforcement of building codes and construction sequence requirements
- Public education about structural safety and the importance of qualified engineers
- Professional accountability with serious consequences for negligence
- Quality assurance through independent inspections at critical stages
Property owners, contractors, and artisans must understand that structural engineering is not an area for experimentation or cost-cutting. The price of structural failure - measured in lives lost, families destroyed, and investments wasted - far exceeds the cost of proper engineering from the outset.
When it comes to structural safety, there are no acceptable shortcuts. If you're planning construction in Kenya, insist on proper structural design by qualified engineers, reject any proposal to place columns on masonry walls, and ensure construction follows the approved structural drawings. Your building's safety - and the lives of its occupants - depend on it.
Disclaimer: This article provides general information about structural engineering principles and should not be considered as specific engineering advice for any particular project. All construction projects must be designed by qualified, registered structural engineers in accordance with applicable building codes and regulations.